Part Number Hot Search : 
29LV0 8602A 1N488 4C10B BUK95 AN6551 LH28F PE4930
Product Description
Full Text Search
 

To Download 60W00K-000 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  technical data sheet 7-16 calibration kit full version 60ck001-150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d-84526 tittmoning germany www.rosenberger.de tel. : +49 8684 18-0 fax : +49 8684 18-499 email : info@rosenberger.de page 1 / 3 picture may differ from original product contents device part number quantity calibration option a open circuit plug 60s12l-000s3 1 fc / ac open circuit jack 60k12l-000s3 1 fc / ac short circuit plug 60s12s-000s3 1 fc / ac short circuit jack 60k12s-000s3 1 fc / ac calibration load plug 60s150-c10s3 1 fc / ac calibration load jack 60k150-c10s3 1 fc / ac calibration adaptor plug/plug 60s121-s20s3 1 fc / a c calibration adaptor jack/jack 60k121-k20s3 1 fc / a c calibration adaptor rpc-n plug to 7-16 plug 05s160-s20s3 1 fc / ac calibration adaptor rpc-n jack to 7-16 jack 05k160-k20s3 1 fc / ac combi wrench 60w013-000 1 - torque wrench 60w000-003 1 fc gauge jack (including gauge block) 60W00K-000 1 fc gauge plug (including gauge block) 60w00s-000 1 fc a. see declaration of calibration options for exp lanation.
technical data sheet 7-16 calibration kit full version 60ck001-150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d-84526 tittmoning germany www.rosenberger.de tel. : +49 8684 18-0 fax : +49 8684 18-499 email : info@rosenberger.de page 2 / 3 documentation this kit is delivered with usb-stick standard definitions as data files for vector netwo rk anaylzer families pna (keysight/agilent) and zva (rohde&schwarz). calibration certificate as pdf-fil e. standard definitions cards printed standard definitions that can be used on ne arly all vector network analyzers. kit info card handling precautions and information for installing standard definitions on a vector network analyzer. calibration certificate details see declaration of calibration options operating manual electrical specifications this specification covers electrical key values for the main calibration standards of the calibration kit. specific datasheets are available for each componen t among the part number. calibration standard frequency parameter specificat ion opens b (plug and jack) dc > 4 ghz to to 4 ghz 8 ghz error from nominal phase 1.0 1.5 shorts b (plug and jack) dc > 4 ghz to to 4 ghz 8 ghz error from nominal phase 1.0 1.5 calibration loads (plug and jack) dc > 4 ghz to to 4 ghz 8 ghz return loss 3 40 db 3 38 db calibration adaptors (plug/plug) dc > 4 ghz to to 4 ghz 8 ghz return loss 3 40 db 3 36 db calibration adaptors (jack/jack) dc > 4 ghz to to 4 ghz 8 ghz return loss 3 38 db 3 34 db calibration adaptors rpc-n to 7-16 (plug/plug and jack/jack) dc > 4 ghz to to 4 ghz 8 ghz return loss 3 36 db 3 33 db b. the specifications for opens and shorts are give n as allowed deviation from nominal model as define d in calibration certificate included with your kit.
technical data sheet 7-16 calibration kit full version 60ck001-150 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d-84526 tittmoning germany www.rosenberger.de tel. : +49 8684 18-0 fax : +49 8684 18-499 email : info@rosenberger.de page 3 / 3 declaration of calibration options factory calibration standard delivery for this kit includes a factory c alibration. all devices marked with fc in the con tent table above are reported in a calibration certifica te with their individual calibration results, trace able to national / international standards. model based def initions of the calibration standards are reported in agilent/keysight, rohde & schwarz and anritsu compa tible vna format. accredited calibration optional this kit can be delivered with an accredit ed calibration (dakks) having the highest confidenc e in the traceability. all devices marked with ac in t he content table above are reported in a dakks cali bration certificate with their individual calibration resul ts in a complex format, traceable to national / int ernational standards. model based definitions of the calibrati on standards are reported in agilent/keysight, rohd e & schwarz and anritsu vna format as well as in dense data sets needed for data based calibration kits. t he uncertainties are a little bit smaller than in a fa ctory calibration. all devices marked with fc only cannot be calibra ted under accreditation. they are factory calibrate d as described above. for further, more detailed information see applicat ion note an001 on the rosenberger homepage. calibration interval recommendation 12 months recommended accessories - rosenberger test port adaptor - rosenberger vna test cable kit and microwave cabl e assemblies for further, more detailed information please visit our homepage www.rosenberger.com . draft date approved date rev. engineering change number name date martin moder 12.10.15 h. babinger 01.08.16 b00 16-1267 m. knoll 01.08.16 while the information has been carefully compiled t o the best of our knowledge, nothing is intended as representation or warr anty on our part and no statement herein shall be construed as recommendation to infringe existing patents. in the effort to improv e our products, we reserve the right to make changes judg ed to be necessary.


▲Up To Search▲   

 
Price & Availability of 60W00K-000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X